WMB-002 is the core equipment for full performance testing of gas wall-mounted boilers. It is deeply compatible with 8 national standards such as GB6932-2015, GB25034-2010, CJ/T395-2012, and can simultaneously complete full-dimensional tests of heat load, energy efficiency, water/gas parameters, wind pressure and electricity (with an accuracy of 0.5% F.S), covering the research and development verification, production line quality inspection and inspection and certification scenarios of water heaters, heating furnaces, and condensing models.

  • Brand :

    HONGCE
  • Model :

    WMB-002
  • Product Origin :

    CHINA
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

 

Product introduction:

  • Seamless coverage of multiple national standards: Integrated hot water (GB6932), heating (GB25034), condensing (CJ/T395) and other 8 national standard test logics, set automatically to adapt to the standard once.
  • Synchronous detection of all parameters: Synchronous acquisition of 20+ parameters such as water flow (0-40L/min), gas pressure (0-10kPa), wind pressure (0-1000Pa), etc., and detection efficiency is increased by 60% (compared with split equipment).
  • 0.5% F.S high precision: Water/gas parameter accuracy reaches 0.5% F.S, gas humidity 0.1% F.S, captures micro deviations (such as 0.1kPa gas pressure fluctuations), and supports accurate determination of energy efficiency levels.

 

National reference standards:

  • GB6932-2015 Hot water performance test: rated heat load, 50% heat load, water temperature fluctuation.
  • GB25034-2010 Heating performance test: rated heat load, 30% heat load.
  • CJ/T395-2012 Condensing model test Condensing heat recovery efficiency, low temperature condition adaptation.
  • GB26655-2015 Energy efficiency grade determination: thermal efficiency, energy consumption limit value.
  • CJ/T336-2010 Condensing instantaneous water heater test: thermal output stability, flue gas emission.

 

Product use:

  • R&D verification: The company's laboratory tests the thermal efficiency and water/gas parameter matching of new products (such as low-temperature conditions for condensing models).
  • Production line quality inspection: Final inspection of the whole wall-mounted boiler factory (heat load, energy efficiency, water/gas parameter compliance, 30+ units tested per day).
  • Inspection and certification: A third-party testing agency issues a test report with the CNAS logo (data is directly used for market access).

 

Technical Parameters

Parameter Technical Details
Model WMB-002
Compliant Standards 8 National Standards (GB6932/GB25034/CJ/T395, etc.)
Hot Water Flow Range 0–30L/min (Sanitary) / 0–40L/min (Heating)
Water Pressure Range 0–1.6MPa (Inlet) / 0–0.6MPa (Circulation)
Water Temperature Range 0–100℃ (Inlet/Outlet/Return)
Gas Pressure Range 0–10kPa (Main) / 0–5kPa (Secondary)
Gas Flow Range 0–5m³/h (Dry: 1% F.S / Wet: 0.5% F.S)
Gas Humidity Range 0–100%RH (0.1% F.S)
Air Pressure Range 0–1000Pa (1% F.S)
Electrical Parameter Range Voltage: 0–300V / Current: 0–4A (1% F.S)
Control Mode PLC + 10-inch Touchscreen HMI
Data Storage ≥5000 Records (USB/Ethernet Export)
Power Supply AC220V±10%/50Hz, 100W
Ambient Temperature 0–40℃ (Non-condensing)
Relative Humidity ≤80% RH
Protection Rating IP30 (Cabinet) / IP40 (Sensor)
Dimensions (L×W×H) 800×600×1200mm (Cabinet)
Equipment Weight 65kg (Main Unit)

 

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Close-up of the electric wall-mounted boiler performance test bench
Source manufacturer Electric wall-mounted boiler performance test bench Accurate detection Supports multiple model testing

This equipment is specially designed for testing the performance of electric wall-mounted boilers. It is committed to providing customers with comprehensive solutions, strictly controlling product quality, improving product competitiveness, and accelerating product research and development.

Details
Overall appearance of wall-mounted boiler durability test equipment
Multi-station wall-mounted boiler durability test equipment ±0.5℃ high-precision temperature control

In the quality control of wall-mounted boilers, the wall-mounted boiler durability testing equipment can help you solve the problem of wall-mounted boiler quality inspection with its accurate testing data and humanized design.

Details
Left view of the comprehensive test bench for wall-mounted boiler parts
High-precision intelligent wall-mounted boiler parts comprehensive test bench Direct supply from the source manufacturer

With humanized design and excellent performance, we provide comprehensive and high-precision solutions for the inspection of wall-mounted boiler parts, helping enterprises to control quality and improve market competitiveness.

Details
Wall-mounted Boiler Testing Equipment
GB6932 Gas Wall-Mounted Boiler Combustion Chamber Sealing Performance Test Equipment 0.6-10m³/H Leakage Test

WMB-001 is the core equipment for detecting the combustion chamber seal of gas wall-mounted boilers. It strictly complies with Article 7.16 of GB6932-2001 "National Standard for Household Gas Instantaneous Water Heaters" to accurately detect the leakage of the combustion chamber. Through the 1.5-level precision flow meter and PLC + touch screen intelligent control, it can realize automatic testing and judgment of the leakage of the sealing structure, and is suitable for wall-mounted boiler production quality inspection, R&D and third-party testing scenarios.

Details
Wall-mounted Boiler Combustion Chamber Tester
Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

WMB-002 is the core equipment for full performance testing of gas wall-mounted boilers. It is deeply compatible with 8 national standards such as GB6932-2015, GB25034-2010, CJ/T395-2012, and can simultaneously complete full-dimensional tests of heat load, energy efficiency, water/gas parameters, wind pressure and electricity (with an accuracy of 0.5% F.S), covering the research and development verification, production line quality inspection and inspection and certification scenarios of water heaters, heating furnaces, and condensing models.

Details
Wall-mounted Boiler Combustion Chamber Tester
Gas Heating Furnace Aging Test Equipment Gb6932/Gb2665 Compliance

WMB-003 is the core equipment for aging test of gas heating furnaces and water heaters. It strictly complies with GB6932-2015 (domestic gas instantaneous water heaters) and GB26655-2015 (energy efficiency limit values) standards, and simulates real aging conditions through computer + PLC intelligent control (precise control of water / gas pressure, temperature, and flow, with an accuracy of 0.5% F.S).

Details
Wall-mounted Boiler Combustion Chamber Tester
Wall-Mounted Boiler Durability Test Equipment Multi-Station Plc Intelligent Control Support Customization

HCTE-WMBT002 is the core equipment for life verification of gas heating water boilers. It supports flexible expansion of 1-50 stations, accurately controls water pressure (0.05-0.5MPa), gas pressure (0.5-5kPa) and water on-off time (0-999s), and realizes 999999 cycles of endurance test through PLC + touch screen control. It is suitable for R&D life verification, production line batch testing and quality inspection and certification scenarios. The core components are imported brands to ensure test stability.

Details
Wall-mounted Boiler Combustion Chamber Tester
Comprehensive Test Bench For Wal Mounted Boiler Parts Multi-Component Integrated Testing

WMBT003 is a full-dimensional test platform for the core components of gas wall-mounted boilers. It integrates four modules: proportional valve air tightness, water flow sensor, burner performance, and pressure resistance test. Through PLC + touch screen intelligent control, it achieves 0.1V voltage resolution and 1-30L/min water flow precision control. It is suitable for wall-mounted boiler R&D verification, production line quality inspection and supplier inspection scenarios. The core valve group adopts imported brands to ensure test stability.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact