enen/ arar
Home Air Conditioner Performance Test System

Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement

Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement

AEEDL-005 is based on the core technology of air enthalpy difference method, accurately simulates the full temperature range of -25℃~60℃ and the humidity environment of 10%~95% RH, and supports 200-6000m³/h air volume and 1-60kW cooling/heating test.

  • Brand :

    HONGCE
  • Model :

    AEEDL-005
  • Certificate :

    Calibration certificate(cost additional)
  • Product Origin :

    China
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement

 

Product Introduction

  • Indoor cabin 10℃~45℃ (±0.1℃), outdoor cabin - 25℃~60℃ (±0.1℃), humidity 10%~95% RH (±2% RH), synchronously collect dry/wet bulb temperature, compressor pressure, electrical parameters (voltage/current/power consumption), air volume differential pressure, noise value and other 15+ parameters, with accuracy reaching industrial standards (air volume ±0.5%, energy efficiency ±1.5%); supports split type (indoor ≤1600×1000×2200mm), multi-split (≤2200×1500×2500mm), window type (≤1200×1200×1200mm), temperature control response ≤8min, automatically generates energy efficiency ratio (EER/COP), energy consumption curve, fault diagnosis report, seamlessly connects to MES system, and shortens R&D cycle by 40%.

 

Product Features

  • Micron-level control: temperature and humidity ±0.1℃/±2% RH, air volume ±0.5%, cooling/heating capacity ±1.5%, data comparison with the National Institute of Metrology deviation < 1.5%;
  • Extreme scenario verification: -25℃ (extreme cold heating), 60℃ (hot summer cooling), 95% RH (high humidity condensation) working conditions, verify the core functions of air conditioner defrosting, anti-freezing, etc.;
  • Multi-parameter coupling analysis: Analyze the correlation between "temperature-humidity-air volume-power consumption-noise", guide air conditioner energy efficiency optimization, noise suppression, and life prediction;
  • Flexible test solution: Supports R32/R410A/R290 and other refrigerant tests, and is suitable for non-standard models such as ultra-thin wall-mounted units, cylindrical cabinets, and top-out multi-split units;
  • Certification Express: Built-in GB/T 7725-2022, ASHRAE 37-2021, ISO 5151:2014 Test template, output data is directly used for China Energy Efficiency Label, US DOE, EU ErP certification;
  • Unmanned operation and maintenance: 12-inch touch screen + remote IoT monitoring, fault self-alarm + preventive maintenance reminder, support 7×24h unattended testing.

 

International reference standards

  • GB/T 7725-2022 Room air conditioner enthalpy difference method test process, temperature and humidity control accuracy, energy efficiency calculation method (mandatory national standard)
  • ASHRAE 37-2021 Environmental simulation accuracy, parameter measurement method and data reporting specification for air conditioning equipment performance test (North American certification core standard)
  • ISO 5151:2014 General performance test method for refrigeration equipment, covering compressor pressure, air volume, energy consumption and other parameter measurements (international general standard)
leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Appearance of air conditioning enthalpy difference chamber
Air Conditioning Enthalpy Difference Chamber Comprehensive Performance Test Temperature And Humidity ±0.1℃ Precise Control

The air conditioning enthalpy difference chamber adopts advanced design concepts and exquisite manufacturing technology. It can simulate various complex environmental conditions and accurately test the performance indicators of the air conditioner.

Details
Appearance of the multifunctional enthalpy difference laboratory
Multifunctional Enthalpy Difference Laboratory Intelligent Air Conditioning Comprehensive Performance Test System ±0.05℃

The multifunctional enthalpy difference laboratory provides all-round support for the performance testing of air-conditioning equipment, saving costs and improving efficiency for enterprises. It is your trustworthy partner in the field of air-conditioning performance testing.

Details
Fresh air unit performance laboratory
Fresh Air Enthalpy Difference Laboratory ISO 16976 Compliant Enthalpy Exchange Efficiency ±1%

AEEDL-004 complies with the GB/T 21087-2020 standard, accurately measures the core parameters of the fresh air unit, such as air volume, enthalpy exchange efficiency, and temperature and humidity exchange rate, supports 100-5000m³/h air volume testing, and can be equipped with world-class sensors (such as Honeywell and Vaisala). It is compared by a national laboratory before delivery (data deviation < 1%), providing authoritative data support for the research and development and quality inspection of fresh air systems.

Details
Appearance of air conditioning enthalpy difference chamber
Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement

AEEDL-005 is based on the core technology of air enthalpy difference method, accurately simulates the full temperature range of -25℃~60℃ and the humidity environment of 10%~95% RH, and supports 200-6000m³/h air volume and 1-60kW cooling/heating test.

Details
Appearance of air conditioning enthalpy difference chamber
Air Conditioning Enthalpy Difference Test Room Multi-Refrigerant Air Conditioning Performance Test System

AEEDL-006 is based on the air enthalpy difference method and constructs an "indoor + outdoor dual-chamber" test system, covering an ultra-wide temperature range of -20~60℃ and an air volume of 200-2000CFM. It is compatible with environmentally friendly refrigerants such as R32/R290, complies with GB 7725-2010 and ISO 5151/13253 standards, and accurately measures core performance of air conditioning such as cooling/heating, defrosting, and energy efficiency (COP/SEER).

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact