enen/ arar
Home Air Conditioner Performance Test System

Multifunctional Enthalpy Difference Laboratory Intelligent Air Conditioning Comprehensive Performance Test System ±0.05℃

Multifunctional Enthalpy Difference Laboratory Intelligent Air Conditioning Comprehensive Performance Test System ±0.05℃

The multifunctional enthalpy difference laboratory provides all-round support for the performance testing of air-conditioning equipment, saving costs and improving efficiency for enterprises. It is your trustworthy partner in the field of air-conditioning performance testing.

  • Brand :

    HONGCE
  • Model :

    HC-ACCPTL002
  • Certificate :

    Calibration certificate(cost additional)
  • Product Origin :

    China
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Multifunctional Enthalpy Difference Laboratory Intelligent Air Conditioning Comprehensive Performance Test System ±0.05℃ 

 

Product Introduction

This multifunctional enthalpy difference chamber is equipped to accurately detect the air volume, rated cooling capacity, rated cooling capacity, rated heating capacity, rated heating capacity, power consumption, COP and IPLV, internal air leakage rate, external air leakage rate, effective ventilation rate, exchange efficiency, etc. of water source heat pumps, chilled water heat pump units, low-temperature air source heat pumps, multi-split air conditioning heat pump units, air-to-air energy recovery devices, combined air conditioning units, air source heat pump hot water units, and fan coil units. The selected sensors and accessories have the characteristics of high measurement accuracy and good stability after long-term practical use. At the same time, we also provide international first-class configuration sensors for customers to choose: the laboratory provides national laboratory prototype comparison test data before delivery to ensure data accuracy.

 

Product Features

 

Intelligent measurement and control, accurate and error-free

 

Equipped with an advanced intelligent measurement and control system, it is like having an experienced engineer guarding the test process at all times. It can collect and analyze a large amount of test data in real time, accurately control key parameters such as temperature, humidity, and air volume, ensure the accuracy and reliability of the test results, and provide solid data support for your product development and quality judgment.

 

Modular design, flexible and changeable

 

Adopting a modular structural design, like building blocks, various functional modules can be flexibly combined according to different test requirements. Whether it is a small household air conditioning test or a large commercial central air conditioning test, it can be easily dealt with, greatly improving the versatility and adaptability of the equipment, saving you equipment procurement and maintenance costs.

 

High-precision sensing, detail control

 

Equipped with high-precision sensors, it is like having a pair of sharp eyes that can capture subtle changes during the test process. The temperature sensor has an accuracy of ±0.1℃, the humidity sensor has an accuracy of ±1.5% RH, and the air volume sensor has an accuracy of ±2%, allowing you to know every detail of the product performance and not miss any factor that affects product quality.​

 

Humanized operation, convenient and efficient​

The operation interface is simple and clear, and adopts a human-computer interaction friendly design, so even first-time users can quickly get started. At the same time, the equipment has functions such as automatic calibration, automatic data recording and analysis, which greatly reduces the tediousness of manual operation, improves test efficiency, and makes your work easier and more convenient.

 

Detail pictures:

 

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Appearance of air conditioning enthalpy difference chamber
Air Conditioning Enthalpy Difference Chamber Comprehensive Performance Test Temperature And Humidity ±0.1℃ Precise Control

The air conditioning enthalpy difference chamber adopts advanced design concepts and exquisite manufacturing technology. It can simulate various complex environmental conditions and accurately test the performance indicators of the air conditioner.

Details
Appearance of the multifunctional enthalpy difference laboratory
Multifunctional Enthalpy Difference Laboratory Intelligent Air Conditioning Comprehensive Performance Test System ±0.05℃

The multifunctional enthalpy difference laboratory provides all-round support for the performance testing of air-conditioning equipment, saving costs and improving efficiency for enterprises. It is your trustworthy partner in the field of air-conditioning performance testing.

Details
Fresh air unit performance laboratory
Fresh Air Enthalpy Difference Laboratory ISO 16976 Compliant Enthalpy Exchange Efficiency ±1%

AEEDL-004 complies with the GB/T 21087-2020 standard, accurately measures the core parameters of the fresh air unit, such as air volume, enthalpy exchange efficiency, and temperature and humidity exchange rate, supports 100-5000m³/h air volume testing, and can be equipped with world-class sensors (such as Honeywell and Vaisala). It is compared by a national laboratory before delivery (data deviation < 1%), providing authoritative data support for the research and development and quality inspection of fresh air systems.

Details
Appearance of air conditioning enthalpy difference chamber
Gb/T7725 Air Conditioning Enthalpy Difference Test Room Multi-Parameter Simultaneous Measurement

AEEDL-005 is based on the core technology of air enthalpy difference method, accurately simulates the full temperature range of -25℃~60℃ and the humidity environment of 10%~95% RH, and supports 200-6000m³/h air volume and 1-60kW cooling/heating test.

Details
Appearance of air conditioning enthalpy difference chamber
Air Conditioning Enthalpy Difference Test Room Multi-Refrigerant Air Conditioning Performance Test System

AEEDL-006 is based on the air enthalpy difference method and constructs an "indoor + outdoor dual-chamber" test system, covering an ultra-wide temperature range of -20~60℃ and an air volume of 200-2000CFM. It is compatible with environmentally friendly refrigerants such as R32/R290, complies with GB 7725-2010 and ISO 5151/13253 standards, and accurately measures core performance of air conditioning such as cooling/heating, defrosting, and energy efficiency (COP/SEER).

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact