enen/ arar
Home Wall-mounted boiler testing equipment

Wall Mounted Boiler Comprehensive Performance Test System ±0.1% Accuracy 32 Full Functions 8 Standards Compatible

Wall Mounted Boiler Comprehensive Performance Test System ±0.1% Accuracy 32 Full Functions 8 Standards Compatible

This flagship platform for full-performance testing of gas wall-mounted boilers integrates 32 heating + hot water test functions, covers ±0.1% accuracy temperature/pressure/flow detection, is deeply compatible with 8 international and domestic standards such as EN625/EN483/GB25034, is equipped with imported core components (with a lifespan of twice that of ordinary equipment), supports MES system docking + power-off memory, and is suitable for R&D critical verification, production line batch quality inspection and international certification pre-inspection.

  • Brand :

    HONGCE
  • Model :

    HCTE-WMBT007
  • Certificate :

    Calibration Certificate(Cost Additional)
  • Product Origin :

    CHINA
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Wall Mounted Boiler Comprehensive Performance Test System ±0.1% Accuracy 32 Full Functions 8 Standards Compatible

 

Product features:

  • ±0.1% level accuracy: ±0.1% accuracy for all parameters of temperature, flow and pressure, minimum scale of 0.001L/min (flow), 0.1℃ (temperature), and no error in critical tests.
  • 32 functions covered: From heating thermal efficiency to hot water overshoot, from gas pressure fluctuation to water channel interpenetration, there is no dead angle in R&D/production line/certification scenarios.
  • 8 standards seamless switching: International (EN625/EN483) + domestic (GB25034/GB6932) 8 standards are automatically adapted, supporting one-click pre-inspection of international certification.
  • Imported component stability control: The core sensor and valve body adopt imported brands, the response speed is ≤30ms, and the parameter fluctuation during the test process is ≤±0.2%.
  • Intelligent data closed loop: PLC + touch screen custom programming, automatic storage of ≥10,000 sets of data, customizable report format, and MES docking to realize intelligent production line.
  • Extreme working conditions expansion: Support high-temperature water inlet (≥ set temperature), 50L constant temperature heating and water replenishment in the bathroom circuit, and adapt to the water channel interpenetration test of condensing models.

 

National reference standards:

  • EN625-1996-Heating performance test: water temperature control deviation, minimum starting flow/pressure (2.5±0.5L/min).
  • EN483-1999-Gas parameter test: gas pressure (1500-3500Pa), flow accuracy (0.04-6m³/h).
  • GB25034-2010-Full performance of heating system: heat output accuracy, water channel pressure resistance (0.5-2.0MPa).
  • GB6932-2015-Full performance of hot water system: thermal efficiency, water stop temperature rise, temperature stabilization time.
  • CJ/T228-2006-Condensing model expansion: water channel interpenetration, condensation heat recovery (optional).

 

Product use:

  • R&D: Verify the critical performance of new products (such as thermal efficiency limit and minimum startup flow rate under ±0.1% accuracy) and accelerate technology iteration.
  • Production line: Batch quality inspection of wall-mounted boilers below 70kW (daily testing ≥120 units), MES docking to achieve intelligent production line, and increase the yield by 20%.
  • Certification: Third-party testing agencies conduct pre-inspection before EN/GB certification, 32 data directly support CNAS certification, and the pass rate is increased by 50%.

 

Technical Parameters

Parameter Technical Details
Model HCTE-WMBT007
Compliant Standards EN625-1996, EN483-1999, GB25034-2010 (8 total)
Temperature Parameters  
Inlet/Outlet Water Temp. Range 0–60℃ / 0–120℃(±0.1% Accuracy, 0.1℃ Resolution)
Gas Temperature Range 0–50℃(Class 0.5 Accuracy, 0.1℃ Resolution)
Pressure Parameters  
Gas Primary Pressure 0–5000Pa(±0.5% Accuracy, 1Pa Resolution)
Gas Secondary Pressure 0–5000Pa(±0.5% Accuracy, 1Pa Resolution)
Inlet Water Pressure High: 0–1.6MPa / Low: 0–1.6MPa(Class 0.5 Accuracy)
Heating System Pressure 0–1MPa(Class 0.5 Accuracy)
Flow Parameters  
Sanitary Water Flow 0–20L/min(±0.1% Accuracy, 0.001L/min Resolution)
Heating Water Flow 0–30L/min(±0.1% Accuracy, 0.001L/min Resolution)
Gas Flow 0.04–6m³/h(±0.1% Accuracy, 1Pa Resolution)
Control & Connectivity  
Control Mode PLC + 15-inch Touchscreen HMI(Custom Programming Support)
Data Storage ≥10,000 Records(Auto-save + Custom Report Formats)
MES Compatibility Temp./Pressure/Flow Data Upload Supported
Environment & Power  
Ambient Temperature 0–40℃(Non-condensing)
Protection Rating IP30(Cabinet) / IP44(Sensor)
Power Supply AC380V±10%/50Hz, 1500W

 

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Close-up of the electric wall-mounted boiler performance test bench
Source manufacturer Electric wall-mounted boiler performance test bench Accurate detection Supports multiple model testing

This equipment is specially designed for testing the performance of electric wall-mounted boilers. It is committed to providing customers with comprehensive solutions, strictly controlling product quality, improving product competitiveness, and accelerating product research and development.

Details
Overall appearance of wall-mounted boiler durability test equipment
Multi-station wall-mounted boiler durability test equipment ±0.5℃ high-precision temperature control

In the quality control of wall-mounted boilers, the wall-mounted boiler durability testing equipment can help you solve the problem of wall-mounted boiler quality inspection with its accurate testing data and humanized design.

Details
Left view of the comprehensive test bench for wall-mounted boiler parts
High-precision intelligent wall-mounted boiler parts comprehensive test bench Direct supply from the source manufacturer

With humanized design and excellent performance, we provide comprehensive and high-precision solutions for the inspection of wall-mounted boiler parts, helping enterprises to control quality and improve market competitiveness.

Details
Wall-mounted Boiler Testing Equipment
GB6932 Gas Wall-Mounted Boiler Combustion Chamber Sealing Performance Test Equipment 0.6-10m³/H Leakage Test

WMB-001 is the core equipment for detecting the combustion chamber seal of gas wall-mounted boilers. It strictly complies with Article 7.16 of GB6932-2001 "National Standard for Household Gas Instantaneous Water Heaters" to accurately detect the leakage of the combustion chamber. Through the 1.5-level precision flow meter and PLC + touch screen intelligent control, it can realize automatic testing and judgment of the leakage of the sealing structure, and is suitable for wall-mounted boiler production quality inspection, R&D and third-party testing scenarios.

Details
Wall-mounted Boiler Combustion Chamber Tester
Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

WMB-002 is the core equipment for full performance testing of gas wall-mounted boilers. It is deeply compatible with 8 national standards such as GB6932-2015, GB25034-2010, CJ/T395-2012, and can simultaneously complete full-dimensional tests of heat load, energy efficiency, water/gas parameters, wind pressure and electricity (with an accuracy of 0.5% F.S), covering the research and development verification, production line quality inspection and inspection and certification scenarios of water heaters, heating furnaces, and condensing models.

Details
Wall-mounted Boiler Combustion Chamber Tester
Gas Heating Furnace Aging Test Equipment Gb6932/Gb2665 Compliance

WMB-003 is the core equipment for aging test of gas heating furnaces and water heaters. It strictly complies with GB6932-2015 (domestic gas instantaneous water heaters) and GB26655-2015 (energy efficiency limit values) standards, and simulates real aging conditions through computer + PLC intelligent control (precise control of water / gas pressure, temperature, and flow, with an accuracy of 0.5% F.S).

Details
Wall-mounted Boiler Combustion Chamber Tester
Wall-Mounted Boiler Durability Test Equipment Multi-Station Plc Intelligent Control Support Customization

HCTE-WMBT002 is the core equipment for life verification of gas heating water boilers. It supports flexible expansion of 1-50 stations, accurately controls water pressure (0.05-0.5MPa), gas pressure (0.5-5kPa) and water on-off time (0-999s), and realizes 999999 cycles of endurance test through PLC + touch screen control. It is suitable for R&D life verification, production line batch testing and quality inspection and certification scenarios. The core components are imported brands to ensure test stability.

Details
Wall-mounted Boiler Combustion Chamber Tester
Comprehensive Test Bench For Wal Mounted Boiler Parts Multi-Component Integrated Testing

WMBT003 is a full-dimensional test platform for the core components of gas wall-mounted boilers. It integrates four modules: proportional valve air tightness, water flow sensor, burner performance, and pressure resistance test. Through PLC + touch screen intelligent control, it achieves 0.1V voltage resolution and 1-30L/min water flow precision control. It is suitable for wall-mounted boiler R&D verification, production line quality inspection and supplier inspection scenarios. The core valve group adopts imported brands to ensure test stability.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact